Файл результата имеет неправильный формат siemens nx
(BULK DATA) (ENTRY). , , (MAT1), (-) , (PTUBE) (PBEND), . , - (Femap ).
2026. USER FATAL MESSAGE 2026, ELEMENT **** GEOMETRY OR MATERIAL PROPERTY YIELDS UN-REASONABLE MATRIX **** , . : (1) - Rod Bar, (2) Bar , (3) Shear Panel , -.
2038. USER FATAL MESSAGE 2038 (RBE3D). RBE3 ELEMENT **** IS SINGULAR RBE3 **** . , - (Independent) (Dependent) , - 6 .
2040. USER FATAL MESSAGE 2040, SINGULAR MATRIX FOR ELEMENT **** - ****. Beam.
2101. USER FATAL MESSAGE 2101 (GP4), GRID POINT **** COMPONENT *** ILLEGALLY DEFINED IN SETS UM US (GRID POINT **** COMPONENT ***) - . , - Constraint Equation (- MPC ) Constraint ( SPC ). , . () Rigid.
2101. USER FATAL MESSAGE 2101 (GP4), GRID POINT **** COMPONENT *** ILLEGALLY DEFINED IN SETS US UR (GRID POINT **** COMPONENT ***) - . , Constraint Equation ( MPC ) Constraint ( SPC ) SUPORT.
2113. USER FATAL MESSAGE 2113 (EMG) ELEMENT ***** REFERENCED MATID **** WHICH CANNOT BE USED TO OBTAIN REQUIRED PROPERTIES **** , . - . , (Rod) -.
3005 USER FATAL MESSAGE 3005 (SOLVE) ATTEMPT TO OPERATE ON THE SINGULAR MATRIX QRR IN SUBROUTINE SOLVE QRR. SUPORT , .
3007. SYSTEM FATAL MESSAGE 3007 (NLITER), ILLEGAL INPUT TO SUBROUTINE NLINIT. - , - , . 3057.
3057. USER WARNING MESSAGE 3057 (NLITER). MATRIX IS NOT POSITIVE DEFINITE - . DOF-spring.
4016. USER FATAL MESSAGE 4016 (GETEMP), THERE IS NO TEMPERATURE DATA FOR *** ELEMENT *** IN SET *** , .
4240. USER FATAL MESSAGE 4240 (TA1BND) BEND ELEMENT *** BEND RADIUS OR ARC ANGLE INCON-SISTENT WITH GEOM OPTION *** , -, Curved Beam.
4295. USER FATAL MESSAGE 4295 (EQD4D) QUAD4 ELEMENT WITH HAS A SINGULAR MEM-BRANE MATERIAL MATRIX. IF MAT2 IS USED, BE SURE G33 IS POSITIVE OR IF MAT8 IS USED, BE SURE G12 IS POSITIVE (QUAD4) **** () . (MAT2) , G33>0, (MAT8) , G12>0.
4298. USER FATAL MESSAGE 4298 (EQD4D), A CORNER POINT MEMBRANE THICKNESS HAS NOT BEEN SPECIFIED FOR ELEMENT WITH AND THERE IS NO DEFAULT VALUE ON THE AS-SOCIATED PROPERTY CARD. , , .
4402. USER FATAL MESSAGE 4402, NO L-SET REMAINS AFTER CONSTRAINTS AND O-SET REMOVED. , (L-set) . -, , L-set -. , .
4551. USER FATAL MESSAGE 4551 (NCONVG), STOPPED PROBLEM DUE TO FAILED CONVERGENCE. - . - .
4660. USER FATAL MESSAGE 4660 (ETX6D) FOR ELEMENT WITH THE GEOMETRY HAS NOT BEEN DEFINED PROPERLY. , X.
4672. USER FATAL MESSAGE 4672 (TA1NLE) PIN FLAG(S) IS(ARE) SPECIFIED FOR ONE OR MORE NONLINEAR CBEAM ELEMENT ENTRIES.
USER INFORMATION: IN NONLINEAR ANALYSIS, THE USE OF PIN FLAGS ON NONLIN-EAR BEAM ELEMENTS IS NOT SUPPORTED. - Beam (Releases) . - Beam -.
4676. USER FATAL MESSAGE 4676, ERROR EXCEEDS ** PERCENT OF YIELD STRESS IN ELEMENT - **** ** %, . . 10.1.13. , - ( Model Load Nonlinear Analysis, Advanced, Stress Fraction Limit). 0.2 (20%). , - . - , , . , . - 9050 9137.
4683. USER FATAL MESSAGE 4683, USER FATAL MESSAGE 4683, DIFF STIFF/STIFF/MASS MATRIX NEEDED FOR EIGENVALUE ANALYSIS () , , . . , : ,
4299 USER FATAL MESSAGE 4299, FOR ELEMENT WITH THE JACOBIAN FOR INTEGRATION POINT NUMBER ** IS LESS THAN OR EQUAL ZERO ID . , -
5272. USER FATAL MESSAGE 5272 (PREMAT) PLASTICITY MODULUS MUST BE LESS THAN THE ELAS-TICITY MODULUS FOR TABLE ID *** -. , *** Plastic.
6174. USER FATAL MESSAGE 6174 (EBEMD) BEAM ELEMENTS WITH OFFSETS ARE NOT SUP-PORTED IN DIFFERENTIAL STIFFNESS OR NONLINEAR ANALYSIS. REMODEL WITHOUT USING BEAMS WITH OFFSET Beam () . - .
6200. USER FATAL MESSAGE 6200 (CASE), TEMPERATURE (INITIAL) COMMAND IS NOT SPECIFIED IN CASE CONTROL. BOTH TEMPERATURE (INITIAL) AND TEMPERATURE (LOAD) MUST BE SPECIFIED IN NONLINEAR STATIC SOLUTION FOR THERMAL LOADS - - , Nonlinear Static .
6202. USER FATAL MESSAGE 6202 (MCE1) THE SELECTED MULTIPOINT CONSTRAINT SET AND/OR RIGID ELEMENTS PRODUCE A SINGULAR RMM MATRIX. THIS MAY BE CAUSED BY A CIRCULAR DEPENDENCY IN WHICH A DEGREE OF FREEDOM IS INDIRECTLY DEPENDENT UPON ITSELF MPC-, Rigid-, . , . - RBE3 , . . 5.8.4.
6312. USER FATAL MESSAGE 6312 (BGCPLD/S) SLAVE GRID POINT =*** AND THE CORRESPONDING MASTER GRID POINTS = ***,*** OF BCONP ENTRY DO NOT LIE IN THE SPECIFIED SLIDE LINE PLANE Slave Master Slide Line - XY , . - .
6499. USER FATAL MESSAGE 6499 (DOM9D) THE OPTIMIZATION ALGORITHM HAS ENCOUN-TERED AN ERROR THAT MAKES FURTHER PROGRESS IMPOSSIBLE. THE GRADIENT OF CONSTRAINT NUMBER NNN IS ZERO CONSTRAINT IS REMOVED FROM THE ACTIVE SET ** THIS IS A VIOLATED CONSTRAINT ** A FATAL ERROR WILL BE GENERATED. , - - . , , ** . , - , , Plate.
6840. USER FATAL MESSAGE 6840 (PREMAT) THE SECOND POINT (X2,Y2) SPECIFIED ON THE TABLES1 BULK DATA ENTRY IS NOT AT THE INITAIL YIELD POINT (LIMIT1) ON THE MATS1 BULK DATA ENTRY WHEN THE TYPE OF MATERIAL NONLINEARITY IS PLASTIC ( ), , -.
7127. USER FATAL MESSAGE 7127 (DOPR3B) DRESP1 BULK DATA ENTRY OF ID NNN REFER-ENCES PTYPE PSHELL PID MMM THERE ARE NO ELEMENTS CORRESPONDING TO THIS COMBINATION. , NNN MMM, - .
7127. SYSTEM FATAL MESSAGE 7127 (DOPR3B) AN ELEMENT WHICH REFERENCES PTYPE *** PID *** IS NOT DEFINED IN THE ANALYSIS MODEL ***, - , .
7342. USER FATAL MESSAGE 7342 (PREMAT) THE FIRST POINT (X1,Y1) SPECIFIED ON THE TABLES1 BULK DATA ENTRY IS NOT LOCATED AT THE ORIGIN OF THE STRESS-STRAIN CURVE . X=0, Y=0.
9050. USER FATAL MESSAGE 9050 (SEKRRS) - RUN TERMINATED DUE TO EXCESSIVE PIVOT RATIOS IN MATRIX KLL. , , ( ), . 19.1.
9058. USER FATAL MESSAGE 9058 (SESTATIC) - THE SOLUTION FOR THE RESIDUAL STRUCTURE DOES NOT EXIST. , , - ( , .. ). , , , - Planar Only, .
9061. SYSTEM FATAL MESSAGE 9061 (IFPL) THE VERSION REQUESTED ON THE RESTART FMS STATEMENT IS NOT VALID FOR RESTART PURPOSES. SUBSEQUENT RESTARTS SHOULD REFERENCE A PRIOR VALID VERSION Nastran, , .
9105. USER FATAL MESSAGE 9105 (PHASE0) A SUPORTI BULK DATA ENTRY IS NOT PRESENT FOR INERTIA RELIEF ANALYSIS (PARAM,INREL,-1). USER ACTION: REMOVE PA-RAM,INREL,-1 OR SPECIFY A SUPORTI BULK DATA ENTRY. Bulk Data , INERTIA RELIEF. INREL, .
9137. USER FATAL MESSAGE 9137 (SEKRRS) RUN TERMINATED DUE TO EXCESSIVE PIVOT RATIOS IN MATRIX KLL. USER ACTION: CONSTRAIN MECHANISMS WITH SPCI OR SU-PORTI ENTRIES OR SPECIFY PARAM,BAILOUT,-1 TO CONTINUE THE RUN WITH MECHA-NISMS. , , ( ), . , PARAM,BAILOUT,-1, . . 19.1.
9155. USER FATAL MESSAGE 9155 (GETLOOP) PARAM, LOOPID, *** DOES NOT CORRESPOND TO A VALID LOOP IDENTIFICATION NUMBER. *** - LOOPID , Nastran . , .
Вопросы/Ответы, не проходите мимо и помогайте новичкам
Илья, фанеру режу, фреза ТВ сплава, 6-ка. 24000 об, 500 подача.
Ребята, а как выключить вращение вертикальной оси вьюпорта? Чтобы при вращении вида фигура не колбасилась вверхногами.
Oleg, курсор в край экрана вниз и вращаешь вправо-влево. В других осях аналогично
Илья, А как выключить горизонтальное вращение оси Z (чтобы горизонт не колбасило)? В любом 3д софте есть такая опция.
Oleg, то есть совсем отключить? Вот с этим не сталкивался. Если не надо вращение по всем осям, то как сказал, курсор в край и в определенной оси вертишь
Подскажите, как написать программу пользовательскую для NX? Нужна программа для построения средней линии.
Подскажите пожалуйста, почему не запускается студия создания шаблонов??
Доброго времени суток. Скажите, пожалуйста, в чём тут проблема. Siemens 8,5. В модуле advance simulation, после успешного проведения расчёта пишет что расчёт завершён. Никакие ошибки не выскакивают. Но не запускает просмотр результатов. Не запускает из-за того что после проведения расчёта не создаётся файл с расширением OP2. В чём может быть причина отсутствия файла с расширением OP2 после расчёта?
Читайте также: